Wp window series sprinklers.
Back to back attic sprinklers.
K5 6 4 12 bb attic.
You can use standard sprinklers or attic sprinklers.
While models bb sd and hip are specific application attic sprinklers.
Part number description mx number.
K5 6 8 12 bb attic.
Cover attics to 60ft.
So add a dry pipe valve compressor to the attic system you installed in florida.
Reliable s grooved products by titus.
Model mx hip specific application attic sprinkler 5 6k part number description mx number.
The tyco model bb back to back sd single directional hip and ap attic plus specific application sprinklers for protecting attics are fire sprinklers for combustible and non combustible sloped attic spaces.
Wet or dry pipe systems.
However it requires the sprinkler to throw water a significant distance to cover its area of protection which leads to high water demand per sprinkler.
Move the same project to montana and you are more than likely going to do a dry pipe system.
You will already have a water supply into the building.
Cpvc is allowed on wet pipe systems only when used with viking s model v sd single directional and vk696 attic upright sprinklers it is possible to utilize a single line of piping at the attic peak eliminating the need for branch lines and greatly reducing the number of required.
150 gpm 250 gpm 250 gpm 300 gpm 100 120 gpm.
Provides a specific cost advantage by reducing the amount of piping required.
The tyco models back to back dual directional bb single directional sd hip and attic plus ap specific appli cation attic sprinklers for protecting attics are fire sprinklers for combus tible and non combustible sloped attic spaces.
Provides a tested method of protecting an attic.
Back to back specific application attic sprinklers globe s new specific application ds re.
The viking model v bb back to back attic sprinklers are ul listed for both wet and dry pipe systems in combustible and non combustible sloped attic spaces and can be installed with steel or cpvc piping.
Wide with a single line of piping eliminating the need for as many as five branch lines.
The model v bb back to back is a specific application attic sprinkler designed to provide superior fire protection in combustible and non combustible sloped attic spaces when compared to standard spray attic protection.
Ddv diaphragm deluge valve.
The model bb sd and hip are specific application attic sprinklers.
Back to back peak style attic sprinklers address the need to minimize spacing between sprinklers by spacing them closely together along the peak of the attic.
300 gpm 500 gpm 340 gpm 400 gpm 120 140 gpm wet system.
K5 6 attic hip.
Kres kfr fusible link sprinklers.
In rack fire sprinkler solutions.
This greatly reduces the growth time of the fire before a sprinkler activates.