Either way the vent will have to go directly to the outside and installed with a vent hood cover.
Bathroom ventilation fan into attic.
No you cannot vent your bathroom exhaust fan into the attic.
Options for venting a bathroom exhaust fan include best to worst.
In all cases the ducting needs to conduct the exchaust to the building exterior and needs to terminate in an animal proof vent cover.
First you ll partially block your roof vent with the piping reducing the flow of cooling air through your attic.
When venting a bathroom exhaust fan make sure to vent the air to the outside rather than into your attic where it can cause mold and mildew to form.
How to install a bathroom vent fan.
The vent hood will have a little flap that opens when air is blowing.
You should never exhaust the bathroom fan directly into the attic.
All municipalities have different requirements but some do not draw a hard line on requiring exhaust fans.
Second during cold winters you ll be blowing warm moist air onto a cold surface the roof vent and roof plywood.
Note that the bathroom vent fan must always exhaust to the outdoors.
Bathroom ventilation codes require a bathroom exhaust fan to vent to the exterior not the attic for health and structural reasons.
This setup requires an in line centrifugal fan mounted in the attic drawing air simultaneously from both bathrooms see photo.
But while you can t have two fans with one vent you can make one fan and one vent serve two bathrooms.
We explain how to install bathroom exhaust fans or vents the vent ducting.
Surprisingly bathroom fans are not required by some building codes.
Bath vent fan installation building codes bath vent fan troubleshooting bath vent fan repair.
The correct way to vent a bathroom fan through an attic is to terminate the vent either to the roof or to the gable wall.
Bathroom exhaust fans perform an important function by removing excess moisture from your home.
You d often blow air from one bathroom into the other and local building inspectors wouldn t approve it.
This article describes routing bath exhaust fan duct upwards through an attic or roof space or downwards through a floor or crawl space.
Never allow the duct to simply blow into an attic crawlspace or other enclosed area.
In those areas ventilation in bathrooms is required but it can be from a window or fan your choice.
Also the installation of the bathroom exhaust fan will go much quicker if you ask a spouse or friend to help be in the attic while you work from below or to hand you tools while you re on.
Your attic is not a temperature controlled environment is never the same temperature as your living space and generally closer to the temperature outside.
If you re tempted to vent your exhaust fan through an existing roof vent or even vent it into the attic don t do it.
How do i properly vent a bathroom fan into an attic.